(I) AUX REMOTE CONTROL W/ TI24 INTERFACE 3P 4P ACTI9

This Acti9 RCA remote control system is dedicated to iC60 circuit breakers. It allows remote electrical control OF of circuit breakers with or without Vigi add-on RCD, with or without auxiliary. It allows circuit breaker reseting after tripping, in accordance with safety principles and regulations in force. The width in 9mm pitches is 7. This device controls 3P, 4P installations with Ti24 interface. it allows local control by operating handle. The Ue rated operational voltage is 230VAC. The operating frequency is 50Hz or 60Hz. The circuit is placed in safety configuration by the padlocking device. 2 choices of operation after tripping are possible (A) Enabling of remote circuit breaker resseting or (B) Inhibition of remote resetting. The version with Ti24 interface allows direct interfacing of remote control with programmable logic controller, supervision system, communication device having inputs/outputs in 24VDC (control, OF and SD indications). The version with Ti24 interface allows fast, reliable connection of the remote control to the Acti9 Smartlink thanks to the prefabricated cables. The version with Ti24 interface allows remote indication by OF potential-free contact, provision of 2 operating modes 1 and 3. The operating temperature is -25°C to + 60°C. The storage temperature is -40°C to + 85°C.

Hover to Zoom

(I) AUX REMOTE CONTROL W/ TI24 INTERFACE 3P 4P ACTI9
  • Corys SKU 0000320440
  • Part No A9C70124
  • Brand SCHNEIDER ELECTRIC LTD (EDI)
  • Corys SKU 0000320440
  • Part No A9C70124
  • Brand SCHNEIDER ELECTRIC LTD (EDI)
  • Industrial Control & Automation

    (I) AUX REMOTE CONTROL W/ TI24 INTERFACE 3P 4P ACTI9

    This Acti9 RCA remote control system is dedicated to iC60 circuit breakers. It allows remote electrical control OF of circuit breakers with or without Vigi add-on RCD, with or without auxiliary. It allows circuit breaker reseting after tripping, in accordance with safety principles and regulations in force. The width in 9mm pitches is 7. This device controls 3P, 4P installations with Ti24 interface. it allows local control by operating handle. The Ue rated operational voltage is 230VAC. The operating frequency is 50Hz or 60Hz. The circuit is placed in safety configuration by the padlocking device. 2 choices of operation after tripping are possible (A) Enabling of remote circuit breaker resseting or (B) Inhibition of remote resetting. The version with Ti24 interface allows direct interfacing of remote control with programmable logic controller, supervision system, communication device having inputs/outputs in 24VDC (control, OF and SD indications). The version with Ti24 interface allows fast, reliable connection of the remote control to the Acti9 Smartlink thanks to the prefabricated cables. The version with Ti24 interface allows remote indication by OF potential-free contact, provision of 2 operating modes 1 and 3. The operating temperature is -25°C to + 60°C. The storage temperature is -40°C to + 85°C.





    Purchased Together





    Purchased Together

    ©Copyright Corys Electrical 2024 - A Sonepar Company.
    ©Copyright Corys Electrical 2024 -
    A Sonepar Company.